Product Details:
Usage/Application | Industrial |
Power | 20HP |
Voltage | 220V |
Power Source | Electric |
Frequency | 50Hz |
Phase | 3 Phase |
Sample volume required | Approx. 12ml |
Bath depth required | 225mm |
Suitable for | Lubricants,transformer , fuel and paint industry |
Material | Glass |
Type | Capillary Tube |
MODEL NO. | SIZE | NOMINAL CONSTANT | VISCOSITY RANGEIN CST |
HAMCO 50B-25 | 25 | 0.002 | 0.5 TO 2 |
HAMCO 50B-50 | 50 | 0.004 | 0.8 TO 4 |
HAMCO 50B-75 | 75 | 0.008 | 1.6 TO 8 |
HAMCO 50B-100 | 100 | 0.015 | 3 TO 15 |
HAMCO 50B-150 | 150 | 0.035 | 7 TO 35 |
HAMCO 50B-200 | 200 | 0.1 | 20 TO 100 |
HAMCO 50B-300 | 300 | 0.25 | 50 TO 250 |
HAMCO 50B-350 | 350 | 0.5 | 100 TO 500 |
HAMCO 50B-400 | 400 | 1.2 | 240 TO 1200 |
HAMCO 50B-450 | 450 | 2.5 | 500 TO 2500 |
HAMCO 50B-500 | 500 | 8.0 | 1600 TO 8000 |
HAMCO 50B-600 | 600 | 20.0 | 4000 TO 20000 |
Product Details:
Brand | HAMCO |
Material | Glass |
Usage/Application | Laboratory |
Number Of Cups | 2 Cups |
Type | BS/U Type Viscometer |
Voltage | 220V |
Power Source | Electric |
Frequency | 60Hz |
Phase | 3 Phase |
MODEL NO. | SIZE | NOMINAL CONSTANT | VISCOSITY RANGEIN CST |
HAMCO 50C-0 | 0 | 0.001 | 0.3 TO 3 |
HAMCO 50C-A | A | 0.003 | 0.9 TO 3 |
HAMCO 50C-B | B | 0.01 | 2 TO 10 |
HAMCO 50C-C | C | 0.03 | 6 TO 30 |
HAMCO 50C-D | D | 0.1 | 20 TO 100 |
HAMCO 50C-E | E | 0.3 | 60 TO 300 |
HAMCO 50C-F | F | 1.0 | 200 TO 1000 |
HAMCO 50C-G | G | 3.0 | 600 TO 3000 |
HAMCO 50C-H | H | 10.0 | 2000 TO 10000 |
Product Details:
Material | Mild Steel |
Usage/Application | Industrial |
Brand | HAMCO |
Type | Suspended Level Long Form |
Voltage | 220V |
Power Source | Electric |
Frequency | 60Hz |
Phase | Single Phase |
Quality | standard |
Country of Origin | Made in India |
MODEL NO. | SIZE | NOMINAL CONSTANT | VISCOSITY RANGEIN CST |
HAMCO 50F-1 | 1 | 0.01 | 3.5 TO 10 |
HAMCO 50F-2 | 1A | 0.03 | 6 TO 30 |
HAMCO 50F-3 | 2 | 0.1 | 20 TO 100 |
HAMCO 50F-4 | 2A | 0.3 | 60 TO 300 |
HAMCO 50F-5 | 3 | 1.0 | 200 TO 1000 |
HAMCO 50F-6 | 3A | 3.0 | 600 TO 3000 |
HAMCO 50F-7 |
Product Details:
Material | Glass |
Usage/Application | Industrial |
Power Source | Electric |
Frequency | 50Hz |
Phase | Single Phase |
Bath depth required | 280mm |
Type | Capillary Tube |
Sample Volume required | 7 ml |
Standard | ISO |
MODEL NO. | SIZE | NOMINAL CONSTANT | VISCOSITY RANGEIN CST |
HAMCO 50D-1 | 1 | 0.003 | 0.6 TO 3 |
HAMCO 50D-2 | 2 | 0.01 | 2 TO 10 |
HAMCO 50D-3 | 3 | 0.03 | 6 TO 30 |
HAMCO 50D-4 | 4 | 0.1 | 20 TO 100 |
HAMCO 50D-5 | 5 | 0.3 | 60 TO 300 |
HAMCO 50D-6 | 6 | 1.0 | 200 TO 1000 |
HAMCO 50D-7 | 7 | 3.0 | 600 TO 3000 |
HAMCO 50D-8 | 8 | 10.0 | 2000 TO 10000 |
HAMCO 50D-9 | 9 | 30.0 | 6000 TO 30000 |
HAMCO 50D-10 | 10 | 100.0 | 20000 TO 100000 |
HAMCO 50D-11 | 11 | 300.0 | 60000 TO 300000 |
Product Details:
Brand | Hamco |
Material | glass |
Usage/Application | Industrial |
Voltage | 220V |
Power Source | Electric |
Made Of | Glass |
Type | Capillary Tube |
Sample volume required | 11 ml |
Suitable for | Lubricants,fuel and transformer oil especially at low temp. |
Bath depth required | 250mm |
MODEL NO. | SIZE | NOMINAL CONSTANT | VISCOSITY RANGEIN CST |
HAMCO 50E-1 | 1 | 0.0008 | |
HAMCO 50E-2 | 2 | 0.003 | 2.1 TO 3 |
HAMCO 50E-3 | 3 | 0.01 | 3.8 TO 10 |
HAMCO 50E-4 | 4 | 0.03 | 6 TO 30 |
HAMCO 50E-5 | 5 | 0.1 | 20 TO 100 |
HAMCO 50E-6 | 6 | 0.3 | 60 TO 300 |
HAMCO 50E-7 | 7 | 1.0 | 200 TO 1000 |
HAMCO 50E-8 | 8 | 3.0 | 600 TO 3000 |
HAMCO 50D-9 | 9 | 10.0 | 2000 TO 10000 |
Product Details:
Usage/Application | Industrial |
Voltage | 220V |
Power Source | Electric |
Frequency | 50Hz |
Suitable For | Polymers At Different Temperature |
Material | Glass |
Sample Volume required | 11 ml |
Bath Depth | 250mm |
Type | Capillary |
MODEL NO. | SIZE | NOMINAL CONSTANT | VISCOSITY RANGE IN CST |
HAMCO 50G-25 | 25 | 0.002 | 0.5 TO 2 |
HAMCO 50G-50 | 50 | 0.004 | 0.8 TO 4 |
HAMCO 50G-75 | 75 | 0.008 | 1.6 TO 8 |
HAMCO 50G-100 | 100 | 0.015 | 3 TO 15 |
HAMCO 50G-150 | 150 | 0.035 | 7 TO 35 |
HAMCO 50G-200 | 200 | 0.1 | 20 TO 100 |
HAMCO 50G-300 | 300 | 0.25 | 50 TO 250 |
HAMCO 50G-350 | 350 | 0.5 | 100 TO 500 |
HAMCO 50G-400 | 400 | 1.2 | 240 TO 1200 |
HAMCO 50G-450 | 450 | 2.5 | 500 TO 2500 |
HAMCO 50G-500 | 500 | 8.0 | 1600 TO 8000 |
HAMCO 50G-600 | 600 | 20.0 | 4000 To 20000 |
Product Details:
Usage/Application | Laboratory |
Power Source | Electric |
Frequency | 50Hz |
Phase | Single |
Sample Volume required | Approx. 7 ml |
Bath Depth required | 203mm |
Material | Glass |
Type | Capillary Tube |
Suitable for | Lubricants, Fuels. |
MODEL NO. | SIZE | NOMINAL CONSTANT | VISCOSITY RANGEIN CST |
HAMCO 50A-25 | 25 | 0.002 | 0.5 TO 2 |
HAMCO 50A-50 | 50 | 0.004 | 0.8 TO 4 |
HAMCO 50A-75 | 75 | 0.008 | 1.6 TO 8 |
HAMCO 50A-100 | 100 | 0.015 | 3 TO 15 |
HAMCO 50A-150 | 150 | 0.035 | 7 TO 35 |
HAMCO 50A-200 | 200 | 0.1 | 20 TO 100 |
HAMCO 50A-300 | 300 | 0.25 | 50 TO 250 |
HAMCO 50A-350 | 350 | 0.5 | 100 TO 500 |
HAMCO 50A-400 | 400 | 1.2 | 240 TO 1200 |
HAMCO 50A-450 | 450 | 2.5 | 500 TO 2500 |
HAMCO 50A-500 | 500 | 8.0 | 1600 TO 8000 |
HAMCO 50A-600 | 600 | 20.0 | 4000 To 20000 |
Product Details:
Material | Glass |
Brand | HAMCO |
Model | HAMCO50 |
Temperature range | 100 Degree C |
Type | Cannon , U Tube , Suspended level , BS/U , Ostwald and size Capillary Glass Viscometer |
Instrument | Scientific |
Additional Information: