Prominent & Leading Manufacturer from Mumbai, we offer semiautomatic flash & fire point apparatus, manual digital flash & fire point test apparatus, manual flash & fire point test apparatus, pensky martene flash point apparatus semiautomatic, automatic pmcc flash point tester and flash point tester.

SEMIAUTOMATIC FLASH & FIRE POINT APPARATUS

REQUEST CALLBACK

Get Best Quote

Approx. Rs 59,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Power (W)1000
Weight (kg)17 kG
Model NumberHAMCO19C
Frequency (Hz)50 HZ
Thermometer (deg. Celsius)400 DEG C
PhaseSINGLE
Power SourceELECTRIC
Automation GradeSemi-Automatic
BrandHAMCO
UsageFLASH POINT
Voltage230 V
ModelHAMCO19C
Operating Voltage230 V
Warranty1 YEAR
Temperature RangeUPTO 400 DEG C
Automation TypeSemi-Automatic

Test Method: - Flash Point is lowest temperature at which application of the ignition source causes the vapor of a specimen of the sample to ignite under the specified condition of the test. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
Standard: - Conforms to the specifications of ASTM D92; IP 36; ISO 2592
Features & Benefits: -
1)     Temp Range: 79 to 400° Deg. C.
2)     Test Method: ISO 2592, ASTM D 92, IP 36, IS 1448 (P-69)
.3)     Ignition Source: Gas Flame with two Pilot electric Coils.
4)     Temperature Sensor: PT-100 in stainless steel sheath.
5)     Flash/Fire Detector: Manual / Visual flash detection.\
6)     Controller: Current regulators which limit the current flowing to the heater, thus give us very accurate control and long life to heater.
7)     Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v or 24V DC, gear motor, vertical movement reciprocating to & fro motion.
8)     Heater: 800 W, 230v.
9)     Electrical ignition for pilot flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.
10)  Equipment Overall Size (LxWxH): 280mm (W) X 530mm ( D ) X 415 mm ( H )
11)  Equipment Gross Weight: 22 Kg.
12)  Equipment supply will be 230 V Ac , 50 Hz with 15 amp capacity.

Accessories Will Be Supplied With Equipment: -

 1)     COC CUP   --  1 NO (CAT NO HAMCO19AC1)
2)     THERMAL FUSE – 1 NO. (CAT NO HAMCO19AC5)
3)     SIGNAL CABLE - 1 NO. ( CAT NO HAMCO 19AC6)

Dimension: - Ixwxh,in.(cm)

11”x22”x17” (28x53x41)
Net Weight: 49 lbs (22kg) 

Shipping Information: - 

 Shipping Weight: 78 lbs (35kg)
Dimensions: 4.7 Cu. ft. 

Ordering Information: -

 

Catalogue No

Product Description

Electrical Requirement

Hamco 19c

Semi-Automatic Flash & Fire Point Apparatus

220-240v, 50/60hz

Hamco 19c Exp.

Semi-Automatic Flash Point Apparatus

115v, 50/60hz

Hamco 19s1

Ceramic Heater

 

Hamco 19s2

 

Thermal Insulator

 

 

 

Hamco 19ac1

 

COC Cup

 

 

 

Hamco 19s3

 

Side Igniter With Coil

 

 

 

Hamco 19s4

Cooling Fan

 

 


Additional Information:

Item Code: HAMCO19C

Pay Mode Terms: T/T (Bank Transfer)

Port of Dispatch: JNPT

Production Capacity: 100

Delivery Time: 3 TO 4 WEEKS

Packaging Details: WOODEN BOX

Yes! I am Interested

View PDF

Manual Digital Flash & Fire Point Test Apparatus

REQUEST CALLBACK

Get Best Quote

Approx. Rs 14,400 / packGet Latest Price

Product Details:

Minimum Order Quantity1 pack
Power (W)800 W
Weight (kg)11 KG
Model NumberHAMCO19B
Frequency (Hz)50
Thermometer (deg. Celsius)400 DEG C
Phase230 V
Power SourceELECTRIC
Automation GradeManual
BrandHAMCO
UsageFLASH POINT DETERMINATION OF LUBRICANT OIL
Voltage230 V
FeaturesMANUAL DETECTION

TEST METHOD :- Flash Point is Lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test.The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
STANDARD :- Conforms to the specifications of:
ASTM D92; IP 36; ISO 2592
FEATURES & BENEFITS :-
1)      Temp.Range: 79  to 400° deg C.
2)      Test Method : ISO 2592 , ASTM D 92 , IP 36 , IS 1448 ( P-69).
3)      Ignition Source : Crank Mechanisam spring loaded with manual handling.
4)      Temperature Sensor : Digital temperature Indicator RTD Type 
5)      Flash/Fire Detector: Manual / Visual flash detection.
6)      Controller: Current regulator which limit the current flowing to the heater, thus give us very accurate control and long life to heater..
7)      Flame-Sampling Arrangement: By Hand.
8)      Heater: 800 W, 230 v.
9)      Equipment Overall Size (LxWxH): 175mm (W) X 300mm ( D ) X 300 mm ( H )
10)  Equipment Gross Weight:12 Kg.
11)  Equipment supply will be 230 V Ac , 50 Hz with 6 amp capacity.

ACCESSORIES WILL BE SUPPLID WITH EQUIPMENT :-
1)      COC CUP   --  1 NO (CAT NO HAMCO19AC1)
2)      THERMOMETER COLLAR – 1 NO ( CAT NO HAMCO19AC2)
3)      DIGITAL TEMPERATURE INDICATOR – 1 NO (CAT NO HAMCO19AC4)

SPARES REQUIRED FOR 5 YEAR TROUBLE FREE OPERATION :-
1)      CERAMIC HEATER  --  2 NOS.(CAT NO HAMCO19S1)
2)      COC CUP  --  2 NO.(CAT NO HAMCO19AC1) 

ELECTRICAL REQUIREMENT
·         220-240V, 50/60Hz, Single Phase, 5.9A
·         OR 115V, 50/60Hz, Single Phase, 11.8A 

DIMENSION :- Ixwxh,in.(cm)
7”x12”x12” (18x30x30)
Net Weight: 27 lbs (12kg) 

SHIPPING INFORMATION :- 

Shipping Weight: 46 lbs (21kg)
Dimensions: 2.75 Cu. ft.       

ORDERING INFORMATION :- 

CATALOGUE NO

PRODUCT DESCRIPTION

ELECTRICAL REQUIREMENT

HAMCO 19B

MANUAL DIGITAL  FLASH & FIRE POINT APPARATUS

220-240V, 50/60Hz

HAMCO 19B EXP

MANUAL DIGITAL  FLASH POINT APPARATUS

115V, 50/60Hz

HAMCO 19S1

CERAMIC HEATER

 

HAMCO 19AC1

 

COC CUP

 

 

 

 


Additional Information:

Item Code: HAMCO19B

Pay Mode Terms: T/T (Bank Transfer)

Port of Dispatch: JNPT

Production Capacity: 100

Delivery Time: 1 WEEK

Packaging Details: CARDBOARD BOX

Yes! I am Interested

View PDF

Manual Flash & Fire Point Test Apparatus

REQUEST CALLBACK

Get Best Quote

Approx. Rs 10,200 / packGet Latest Price

Product Details:

Minimum Order Quantity1 pack
Power (W)800 W
Weight (kg)9 KG
Model NumberHAMCO19A
Frequency (Hz)50
Thermometer (deg. Celsius)400 DEG C
PhaseSINGLE
Power SourceELECTRIC
Automation GradeManual
BrandHAMCO
UsageFLASH POINT DETERMINATION
Voltage230 V

TEST METHOD :- Flash Point is Lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test.The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
STANDARD :- Conforms to the specifications of:ASTM D92; IP 36; ISO 2592
FEATURES & BENEFITS :-
1)      Temp.Range: 79  to 400° deg C.
2)      Test Method : ISO 2592 , ASTM D 92 , IP 36 , IS 1448 ( P-69).
3)      Ignition Source : Crank Mechanisam spring loaded with manual handling.
4)      Temperature Sensor : Thermometer .
5)      Flash/Fire Detector: Manual / Visual flash detection.
6)      Controller: Energy regulator manual type.
7)      Flame-Sampling Arrangement: By Hand.
8)      Heater: 800 W, 230 v.
9)      Equipment Overall Size (LxWxH): 175mm (W) X 200mm ( D ) X 275 mm ( H )
10)  Equipment Gross Weight: 8 Kg.
11)  Equipment supply will be 230 V Ac , 50 Hz with 6 amp capacity.
ACCESSORIES WILL BE SUPPLID WITH EQUIPMENT :-
1)      COC CUP   --  1 NO (CAT NO HAMCO19AC1)
2)      THERMOMETER COLLAR – 1 NO ( CAT NO HAMCO19AC2)
3)      THERMOMETER ASTM 11C – 1 NO (CAT NO HAMCO19AC3)

SPARES REQUIRED FOR 5 YEAR TROUBLE FREE OPERATION :-
1)      CERAMIC HEATER  --  2 NOS.(CAT NO HAMCO19S1)
2)      COC CUP  --  2 NO.(CAT NO HAMCO19AC1)
3)      THERMOMETER ASTM 11C – 1 NO (CAT NO HAMCO19AC3)
ELECTRICAL REQUIREMENT
·         220-240V, 50/60Hz, Single Phase, 5.9A
·         OR 115V, 50/60Hz, Single Phase, 11.8A 

DIMENSION :- Ixwxh,in.(cm)
7”x8”x11” (18x20x28)
Net Weight: 18 lbs (8kg) 

SHIPPING INFORMATION :- 

Shipping Weight: 33 lbs (15kg)
Dimensions: 1.75 Cu. ft.      

ORDERING INFORMATION :- 

CATALOGUE NO

PRODUCT DESCRIPTION

ELECTRICAL REQUIREMENT

HAMCO 19A

MANUAL FLASH & FIRE POINT APPARATUS

220-240V, 50/60Hz

HAMCO 19A EXP

MANUAL FLASH POINT APPARATUS

115V, 50/60Hz

HAMCO 19S1

CERAMIC HEATER

 

HAMCO 19AC1

 

COC CUP

 

 

 

HAMCO 19AC3

 

THERMOMETER ASTM 11C

 

 

 

 


Additional Information:

Item Code: HAMCO19A

Pay Mode Terms: T/T (Bank Transfer)

Port of Dispatch: JNPT

Production Capacity: 100

Delivery Time: 1 WEEK

Packaging Details: CARDBOARD BOX

Yes! I am Interested

View PDF
Save time! Get a Best Deal

*Your information is safe with us.

PENSKY MARTENE FLASH POINT APPARATUS SEMIAUTOMATIC

REQUEST CALLBACK

Get Best Quote

Approx. Rs 65,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
BrandHAMCO
Temperature Range370 DEG C
Stirring Speed120 & 250 RPM
Accuracy0.1 DEG C
Power Supply230 V
Usage/ApplicationFLASH POINT
ModelHAMCO30C

Introduction: 

"HAMCO" make Semi-Automatic Penske Marten Flash Point Apparatus are designed & fabricated to suit various  ASTM, IP & I.S. standards application in the growing field of petroleum, grease, Biodiesel ,Pharmaceutical  Research Laboratories & Various Industries.  It has a cutting edge technology to challenge & maintain Climatic conditions above freezing what so ever & where ever you need.


 

Features:
a) Temperature room temp. . To 3700C
b) Digital Display Electronic Temperature
 Controller with an accuracy of +/-0.50C                                                                                                 

 

 

 

 

 

 

 

SPECIFICATIONS 

 

 

 

  • It determines the flash point by semi-automatic pensky martene closed cup tester of fuel oils, lube oils, suspension of solids, liquids that tend to form a surface film under test conditions, and other liquids.
  • HAMCO 30C Semiautomatic Pensky Martene flash point apparatus electrically heated can be controlled by energy regulator or voltage variac.
  • It can be heated electrically or by gas also.
  • Dual speed - Deluxe model.
  • With oil cup, lid, gas ignition device.
  • Electric driven stirring device with dual speed 90-120 rpm and 250 rpm.
  • Air arrangement for cooling.
  • Energy regulator temperature controller with temperature indicator.
  • Gas ON/OFF valve.
  • Power supply: 230 V, 1 Phase, 50 Hz, 8 A total load.
  • Size of the equipment approximately 330mm X 310mm X 290mm.
  • Weight approx: 8.0 Kg.   

 

 

 

 

Dimension: - Ixwxh, in.(cm)
11”x22”x17” (28x53x41)
Net Weight: 49 lbs (22kg)

 

Shipping Information:- 

Shipping Weight: 78 lbs (35kg)
Dimensions: 4.7 Cu. ft.      

 


Additional Information:

Item Code: HAMCO30C

Pay Mode Terms: T/T (Bank Transfer)

Port of Dispatch: JNPT

Production Capacity: 100

Delivery Time: 3 WEEKS

Packaging Details: WOODEN BOX

Yes! I am Interested

View PDF

Automatic PMCC Flash Point Tester

REQUEST CALLBACK

Get Best Quote

Approx. Rs 3.75 Lakh / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
BrandHAMCO
Automation GradeAutomatic
Temperature Range40 TO 400 DEG C
Stirring Speed120 & 250 RPM
Accuracy0.1 DEG C
Power Supply230 V
FeaturesAutomatic
Usage/ApplicationFlash Point Determination

Test Method: - Flash Point is lowest temperature at which application of the ignition source causes the Vapour of a specimen of the sample to ignite under the specified condition of the test.The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached.
Standard: - Conforms to the specifications of:ASTM D93; IP 34; ISO 2719
Features & Benefits:-
1)     Temp. Range: 40 to 400° deg C.
2)     Test Method: ISO 2719, ASTM D 93, IP 34, IS 1448 (P-21).
3)     Ignition Source: Electrical ignitor with LPG gas connection.
4)     Temperature Sensor: PT-100 in stainless steel sheath.
5)     Flash Detector: CRC Thermocouple.
6)     Controller: Touch Screen, Colour Display with PLC with audio visual alarm to check the machine. 3-wire RTD temperature sensor, free potential flame detector sensor as i/p. with automatic barometric reading correction.
7)     Inbuilt storage memory for Flash Detection.
8)     Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v or 24V DC, gear motor, vertical movement reciprocating to & fro motion.
9)     Heater: 800 W, 230v.
10)  Electrical ignition flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.
11)  Equipment Overall Size (LxWxH): 280mm (W) X 530mm ( D ) X 415 mm ( H )
12)  Equipment Gross Weight: 22 Kg.
13)  Equipment supply will be 230 V Ac, 50 Hz with 15 amp capacity.
Features:-Single Action Setting: - The Flash Detection sensor and temperature sensor are permanently mounted on a lid, which allows easy setting of the specimen.Easy Operation: - Select a Test Mode and enter the expected flash Point. While instrument executes the test, you are free to do other lab work. The tester follows the exact procedures prescribed in the test method and the completion of the test cycle is signalled by buzzer. The test result is brightly shown in VFD and same will be stored in the HMI.
Automatically Shut The Machine And Horn The Buzzer In The Case:

1

EFP+30oC or at 400oC is reached

2

Temperature sensor is found defective

3

Flash detector is found defective

 

Accessories Will Be Supplied With Equipment:-
1)     Pensky Martene  Cup & Lid  --  1 No (Cat No Hamco30ac1)
2)      Thermal Printer  -- 1 No (Cat No Hamco30ac7)
3)     Thermal Printer Roll  --  1 No (Cat No Hamco30ac8)
4)     Pc Interface Cable – 1 No. (Cat No Hamco30ac9)
5)     Software For Above-- 1 No. (Cat No Hamco30ac10)
6)     Thermal Fuse – 1 No. (Cat No Hamco30ac5)
7)     Signal Cable - 1 No. ( Cat No Hamco 30ac6)
Ordering Information:-

Catalogue No

Product Description

Electrical Requirement

Hamco 30D

Automatic Pensky Martene Flash Point Apparatus

220-240v, 50/60hz


Additional Information:

Item Code: HAMCO30D

Pay Mode Terms: T/T (Bank Transfer)

Port of Dispatch: JNPT

Production Capacity: 10

Delivery Time: 4 TO 6 WEEK

Packaging Details: WOODEN BOX

Yes! I am Interested

View PDF

Flash Point Tester

REQUEST CALLBACK
  • Flash Point Tester
  • Flash Point Tester
  • Flash Point Tester
  • +1 Flash Point Tester

Ask for Price

Product Price: Ask Latest Price

Product Details:

Temp.RangAmbient to 400oC
Test MethodISO 2592 , ASTM D 92 , IP 36 , IS 1448 ( P-69).
Ignition SourceGas Flame with two Pilot electric Coil.
Temperature SensorPT-100 in stainless steel sheath.
Flash/Fire DetectorIonization principle based flash-detector sensor
Equipment Gross Weight16 Kg. Equipment supply will be 230 V Ac , 50 Hz with 15 amp capacity.
Equipment Overall Size230mm (W) X 470mm ( D ) X 385mm ( H )

This flash point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method. Its primary use is for viscous materials having a flash point between 79°C (175°F) and 400°C (752°F) except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations.

The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions

  • The flash point is the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite.

  • To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s.

It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same instrument without any additional equipment. For substances with unknown flash points, the APPARATUS has a special search mode program. During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash point of a specimen can thereby be found in a time saving and economical manner.

  • Optional On demand: When examining highly viscous specimens, a preheating time and temperature are set in order to warm-up and liquefy the sample to inserted temperature probe without problem. Further a skimmer is removing the surface skin from bituminous samples.

  • Standard Cup with handle, made of brass

  • Temperature Probe Pt-100 for sample temperature

  • Electric Gas Igniter with connector cable and plugs

Flame Detection Unit for the detection of flash- and fire-points Flame Arrest Cover for extinguishing the fire in the cup PC Interface Programmed Controller. The Unit is incorporated with MODBUS RTU PC interface Microprocessor based PID Programmable
controller user friendly features.


Details:

Fully Automatic Flash and Fire point apparatus.

  • Controller: Microprocessor based process controller cum indicator with touch screen with LED Display with audio visual alarm to check the machine. 3-wire RTD temperature sensor, free potential flame detector sensor as i/p. The controller having capacity of storing 200 data with automatic barometric reading correction.

  • It is with PC Interface for data storing.

  • Printer with data interface cable for taking the reading of Flash Point after completion of the cycle.

  • Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v or 24V DC, gear motor, vertical movement reciprocating to & fro motion.Heater: 800 W, 230 v.

  • Electrical ignition for pilot flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.