We are one of the manufacturers of the best quality Scientific Instruments for more than four decades.
|
|
| Pensky Martene Flash Point Apparatus Introduction : "HAMCO" make pensky martene flash point apparatus are designed & fabricated to suit various ASTM, IP & I.S. standards application in the growing field of petroleum, grease, Biodiesel ,Pharmaceutical Research Laboratories & Various Industries. It has a cutting edge technology to challenge & maintain Climatic conditions above freezing what so ever & where ever you need. Features : - Temperature room temp. . To 3700C
- Digital Display Electronic Temperature
- Controller with an accuracy of +/-0.50C .
SPECIFICATIONS - It determines the flash point by pensky martene closed cup tester of fuel oils,lube oils, suspension of solids, liquids that tend to form a surface film under test conditions,and other liquids.
- HAMCO 30 Pensky Martene flash point apparatus electrically heated can be controlled by energy regulator or voltage variac.
- It can be heated electrically or by gas also.
- Dual speed - Deluxe model.
- With oil cup, lid, gas ignition device.
- Electric driven stirring device with dual speed 90-120 rpm and 250 rpm.
| 
| Water Still Introduction : “HAMCO” make water still are designed and fabricated to suit various I.S. standards to filter water from impurities, dissolved salts & odour in the field of Medical, Agricultural, Industrial, Research laboratories and Hospitals. Features : - Pyrogen free distilled water.
- Complete Stainless Steel.
- Wall mounting.
Application : General laboratory purpose water distillation plant Specification : | Models | HAMCO-28a | HAMCO-28b | HAMCO-28c | HAMCO-28d | | Capacity | 2 ltrs | 4 ltrs | 6 ltrs | 8 ltrs | | Chamber | Stainless Steel 304 quality | | Air Heater | Kettle Heater ISI Mark | | Heat up Time | 30 min. from Ambient | | Mounting | Clamp for wall mounting | | Top Lid | Stainless Steel | | Capacity (Watts) | 1500 | 3000 | 4000 | 6000 | | Power Consumption | 6 amps | 12 amps | 16 amps | 25 amps | | Electric Requirements | | 
| Chiller We bring broad gamut of glycol chillers and glycol air chillers for various applications and varying temperatures ranging from +35°C to -50°C. Our glycol chillers, glycol air chillers and air chillers are exceptional, compact and latest technology oriented. The use of semi-hermetic compressors have made our glycol air chiller and air chillers highly energy efficient. Further, the use of sophisticated two stage compressors with sub-cooler and related accessories have simplified the achievement of temperatures as low as -50 C. Our chillers, air chillers and glycol chillers can be integrated with insulated brine storage tank & re-circulating pump application chemical process plants anodizing / electroplating plants laboratory applications Latex cooling In order to select the best chiller for low temperature application, specify the following details to enable us to recommend an optimum system. Required media temperature Heat load Air / water cooled condenser Ambient temperature at site of installation | 
| All Quartz Double Water Distillation Apparatus Water distillers produce highly treated and disinfected water for laboratory usage. The distillation process removes minerals and microbiological contaminants and can reduce levels of chemical contaminants. Water distillers are neither intended to treat water that is visually contaminated nor intended to convert waste water to safe, micro biologically. Working Principle A water distiller works by boiling water into water vapor, condensing it and then returning it to its liquid state. It is collected in a storage container. The process occurs in several steps: - Municipal or well water is manually or automatically fed into the distiller unit’s boiling chamber.
- A heating element in the boiling chamber heats the water until it boils.
- The steam rises from the boiling chamber. Volatile contaminants (gases) are discharged through a built-in vent. Minerals and salts are retained in the boiling chamber as hard deposits or scale.
- The steam enters a coiled tube (condenser), which is cooled by cool water.
- Water droplets form as condensation occurs.
- He distilled water is collected in a storage tank. If the unit is an automatic model, it is set to operate to fill the storage tank
Features: Quartz distiller, Demountable boiler. Compact design, Dual safety cutout(optional). High purity, low conductivity, Pyrogen free distillate. Easy service and maintenance due to Demountable model. Technical Specifications:Quartz distiller, Demountable boiler. Compact design, Dual safety cutout(optional). High purity, low conductivity, Progeny free distillate. Easy service and maintenance due to Demountable model. Technical Specifications:
| Output Capacity (Approx.) | 1 ltr/hr | 1.5 ltr/hr | 2 ltr/hr | 2.5 ltr/hr | 3.0 ltr/hr | 5.0 ltr/hr | | Electrical Power Reqd. | 220/240 V, Single Phase, 2.0 KW Heater | 220/240 V, Single Phase, 3.0 KW Heater | 220/240 V, Single Phase, 3.5 KW Heater | 220/240 V, Single Phase, 4.5 KW Heater | 220/240 V, Single Phase, 5.0 KW Heater | 440 V, Two Phase, 8.0 KW Heater | | Cooling Water Consumption | 40 lit/hr | 50 lit/hr | 65 lit/hr | 70 lit/hr | 100 lit/hr | 150 lit/hr | | 
| Drum Heater Vertical heating system for 200 Ltr standard drum with total rating 12 Kw, 3 phase,50 Hz. Base Heater for drum is also available. | 
| Muffle Furnace We manufacture laboratory furnaces that can make the temperature rise upto 1450°C and are used for continuous heating for processing samples and materials in a laboratory. These laboratory furnaces are built using refractory materials in order help maintaining high temperatures for a longer duration. These furnaces are manufactured keeping in mind that they can be sometimes used to work for many days or months for completing a process set. Application areas: Laboratory furnaces are used in number of industries including: - Pharmaceuticals
- Chemicals and Petrochemicals
- Refineries
- Clinical Laboratory
- Research Laboratory
| 
| Vacuum Oven We manufacture double walled vacuum ovens. The outer of these ovens is made using mild steel sheets that are duly enamel & painted to protect from corrosion. The interior is made of heavy gauge stainless sheet to stand high temperature. To avoid the thermal loss the gap between the two walls is filled using the glass wool. The temperature is controlled using digital temperature controller. This is made to work on 220/230 Volts A.C. supply. | 
Capillary Glass Viscometer We Manufacture complete range of Glass Viscometer with constant @ 40 deg C , @ 50 deg C , @ 100 deg C treacable to cannon Oil USA. We make all type like Cannon , U Tube , Suspended level , BS/U , Ostwald and size Capillary Glass Viscometer. | 
Oil Bath Double Wall Construction. Inside SS , outside MS Powdercated with motorised stirrer with digital temperature controller . Temp. range room temperature to 250 degree C.Accuracy of control +/- 0.2 degree C. | 
|