Product Details:
Minimum Order Quantity | 1 Piece |
Finishing | CNC Finished |
Frequency | 50 Hz |
Model Name/Number | HAMCO 65C |
Dial Gauge | Digital |
Extension Rod Size | 3.5 |
Shipping Dimensions | 25 X 20 X 40 CM |
Automation Grade | Automatic |
Heating Load | 1000 Watt |
Tube Size | 600 ML |
Phase | Single Phase |
Display Type | HMI Touchscreen Color Display |
Country of Origin | Made in India |
Mounting Type | Table Top |
Drop Height | 25 mm |
Calibration Bar | 0-250 Deg C |
Size/Dimension | Two sample at a Time |
Weight | 23 Kg |
Temperature Measuring Range | Up to 250 Deg C |
Driven Type | Magnetic Stirring |
Rotation | By Stirring |
Color | WHITE |
thermometer IP | IP 36 |
Power | 1000 Watt |
Brand | HAMCO |
Steel ball | 2 Nos |
Two steel balls each | yes |
Material | GI Duly Powder Coated |
I Deal In | New Only |
Softening Point | Automatic Type |
Capacity | 2 Sample at a time |
Pressure | Atmospheric |
Usage/Application | Wax, Bitumen, Grease, Cream , Semi solid etc |
Pan Size | 50 mm |
Diameter | 9.8 mm |
Glass Jar Capacity | 600 ML |
Dimension | 25 X 20 X 40 CM |
Internal dia | 9.8 mm |
Voltage | 230 V Ac |
Balance Sensitivity | 0.1 |
Detection | Fully Automatic |
Sensor Type | Optical Fibre |
Printer | Yes Thermal Printer |
Media | Water/ Glycerin / Silicon |
Memory | 400 Data |
PC Software | Yes Desktop Based |
Standard | ASTM D 36 |
Time | 10-15 Min |
Additional Information:
Product Details:
Material | MS |
Brand | HAMCO |
Frequency | 50-60 Hz |
Temp.Rang | Ambient to 400oC |
Ignition Source | Gas Flame with two Pilot electric Coil. |
Temperature Sensor | PT-100 in stainless steel sheath. |
Flash/Fire Detector | Ionization principle based flash-detector sensor |
Equipment Overall Size | 230mm (W) X 470mm ( D ) X 385mm ( H ) |
Power Source | Electric |
Voltage | 220-380V |
This flash point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method. Its primary use is for viscous materials having a flash point between 79°C (175°F) and 400°C (752°F) except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations.
The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions
The flash point is the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite.
To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s.
It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same instrument without any additional equipment. For substances with unknown flash points, the APPARATUS has a special search mode program. During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash point of a specimen can thereby be found in a time saving and economical manner.
Optional On demand: When examining highly viscous specimens, a preheating time and temperature are set in order to warm-up and liquefy the sample to inserted temperature probe without problem. Further a skimmer is removing the surface skin from bituminous samples.
Standard Cup with handle, made of brass
Temperature Probe Pt-100 for sample temperature
Electric Gas Igniter with connector cable and plugs
Flame Detection Unit for the detection of flash- and fire-points Flame Arrest Cover for extinguishing the fire in the cup PC Interface Programmed Controller. The Unit is incorporated with MODBUS RTU PC interface Microprocessor based PID Programmable
controller user friendly features.
Details:
Fully Automatic Flash and Fire point apparatus.
Controller: Microprocessor based process controller cum indicator with touch screen with LED Display with audio visual alarm to check the machine. 3-wire RTD temperature sensor, free potential flame detector sensor as i/p. The controller having capacity of storing 200 data with automatic barometric reading correction.
It is with PC Interface for data storing.
Printer with data interface cable for taking the reading of Flash Point after completion of the cycle.
Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v or 24V DC, gear motor, vertical movement reciprocating to & fro motion.Heater: 800 W, 230 v.
Electrical ignition for pilot flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.
Product Details:
Color | White |
Size | Single,double,triple |
Display Type | Digital |
Accuracy (%) | 0.1 % |
Power Source | Electric |
Power Supply | 230 V |
Digital Timer And Counter | 9999 |
Brand | Hamco |
Usage/Application | Foaming Characteristics Of Oil |
TEST METHOD :- Foaming of lubricating oils in applications involving turbulence, high speed gearing or high volume pumping can cause inadequate lubrication, cavitation, overflow and premature oxidation. The sample is blown with a controlled volume of air at different specified temperatures, including a newer high temperature test at 150°C. The resultant foam is measured at the end of each aeration period and at different intervals afterward. In the high temperature test, the amount of time required for the foam to collapse to “0” after the aeration period is also measured.
STANDARD :- Conforms to the specifications of:ASTM D892, D6082; IP 146; DIN 51566; FTM 791-3211; NF T 60-129,Temperature Control:Digital Setpoint and Displays °C/°F switchable.
Features & Benefits :
1) Type Of Bath :- Electrically Heated Immerssion Heater.
2) Max Working Temperature :- 160 Degree C
3) Continous Working Temperature :- 150 Degree C.
4) Capacity :- 1 Sample At A Time(hamco22a),2 Sample(hamco22b), 3 Sample(hamco22c).
5) Heater :- Immerssion Heater.
6) Accuracy :- +/- 0.3 Degree C.
7) Readability :- +/- 0.1 Degree C.
8) Temperature Controller :-
a. Temp. Is Controlled By Microprocessor Based Pid Temp. Controller ,
b. It Is Having Dual Display With Lnt Or Siemens Contactor For Switching On & Switching Off The Heater.
9) Input Power Supply : 230 V Ac, 50 Hz, 1 Phase With 10 Amp Current Rating.
10) Heating Load : 3 Kw .
11) Thermocouple :-
a. Calibrated Rtd Type Thermocouple Will Be Provided Capable Of Measuring Upto 120 Deg C At Accuracy Of +/- 0.1 Deg C.
12) Control Panel/display :-
a. Digital Display For Present , Set Temperatures .
b. Heater Indicator.c. Main Switch On/off Indicator.
13) Safety Interlocks/ Relay :-
a. Overload Safety Cut-off.
b. Safety For Input Power Fluctuation.
c. 1-phase Indication Lamp.d. Emergency Switch Off.
14) Construction :-
a. Double Walled Construction , Thermally Insulated With Cooling System For Better Performance During Continous Operation.
b. Powder Coated External Surface For Esthatic Appearance.
Ordering Information :-
CATALOGUE NO | PRODUCT DESCRIPTION | ELECTRICAL REQUIREMENT |
HAMCO 22A | FOAMING TEST APPARATUS (SINGLE). TEMP 24/93.5/150 | 220-240V, 50/60Hz |
HAMCO 22B | FOAMING TEST APPARATUS (DOUBLE). TEMP 24 & 93.5/150 | 220-240V, 50/60Hz |
HAMCO 22C | FOAMIN TEST APPARATUS (TRIPLE) TEMP 24&93.5&150 | 220-240V, 50/60Hz |
Product Details:
Range | Room temp. to 150 deg C |
Brand | Hamco |
Standard | ASTM D 445 ,IP 71 |
Material | Stainless Steel |
Accuracy | +/- 0.1 degree centigrade |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
Product Details:
Temperature | 0 dg C, -17dgC, -34 dgC &-51dgC |
Controller | PID |
Material | Stainless Steel |
Brand | Hamco |
Standard | IP 15 & 219 ASTM-D 2500& IS 1448 (P-10) |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
Product Details:
Stirring Speed | 250 rpm. |
Accuracy | +/-0.50C |
Display | Led Numeric |
Brand | Hamco |
Dual speed | Deluxe model |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
Product Details:
Unit Pack Size | 1 |
Brand | HAMCO |
Automation Grade | Automatic |
Voltage (V) | 230 V |
Power (W) | 2000 |
Appearance Of Solution | white |
Temperature (Deg. Celsius) | upto 90 deg c |
Usage/Application | Oil testing equipment |
Weight (g) | 60 Kg |
Test Method: - This test method covers measurement of the ability of petroleum oils or synthetic fluids to separate from water. A Cylindrical Bath is made up of Glass with cylinder holder assy. to holds Graduated Cylinder 6 Nos. firmly with the clamps. A provision is made to rotate manually the Cylinder Holder Assembly which permits to locate the cylinders exactly below the blade of the stirrer. All 6 samples can be checked one after the other.
Standard: - ASTM D1401, D6074, D6158; ISO 6614;DIN 51599; FTM 791-3201; NF T 60-125
Features & Benefits:-
· Stirring Range :- 1100 to 1600 RPM.
· Accuracy :- +/- 25 RPM.
· Bath Temperature :- Ambient +5 deg C to 90 deg C.
· Control stability :- +/- 0.5 deg c.
· Capacity :- 6X 100 ml graduated Cylinder
· Medium :- Water or white technical oil.
· Temperature controller :- Digital display PID controller type.
· Sensor :- PT 100
· Heater :- Stainless steel 1500 watt.
· Timer :- 99 Min 59 sec preset timer.
· Bath circulator :- Motorised.
· Illumination :- Rear Illumination.
Description :- Constant temperature bath with stirrers for water seperability test. Load the 100 ml test cylinder with 40ml sample, 40 ml water . Load the cylinder in bath at 54 +/- 1 deg c. Stirs sample-water mixtures at 1500rpm for 5 minutes and record the volume of oil and water after 5 minutes.
Accessories Will Be Supplied With Equipment:-
1) Graduated 100 ml cylinder for water seperatability (Model HAMCO 95AC1) -- 6 Nos. 2) Rear Illumination -- 1 Nos.
Dimension: - Ixwxh,in, (cm)lxwxh, in.(cm): 20.75x15.25x29.5 (52.7x38.75x 74.9),Net Weight: 83 lbs (37.6 kg)
Shipping Information:-Shipping Weight: 188 lbs (85.3 kg),Dimensions: 34x27x40 in. (86.4x68.6x101.6 cm)
Ordering Information:-
Catalogue no | Product description | Electrical requirement |
Hamco 95 | Water seperability of petroleum oils | 230V Ac,50 Hz, 10 A |
Hamco 95ac1 | Graduated cylinder 100 ml |
|
Additional Information:
Product Details:
Net Weight | 10 lbs (4.5kg) |
Shipping Weight | 16 lbs (7.3 kg) |
Shipping Dimensions | 5 Cu. ft. |
Brand | Hamco |
Dimension | 18 X 47 cm |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
Product Details:
Material | Stainless Steel |
Machine Type | Oil Testing |
Automation Grade | Semi Automatic |
Brand | Hamco |
Standard | ASTM |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
Product Details:
Material | SS |
Brand | HAMCO |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
Phase | 1 Phase |
Test Method: -Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures.
Standard: -Conforms to the specifications of: ASTM D445, D2532, D6074, D6158, IP 71, ISO 3104, DIN 51550;FTM 791-305.
Features & Benefits: -
1) Type of bath: - electrically heated round bath.2) No of viscometer can be accommodated: 5 no.
3) Inner chamber dimension: 12” dia x 12” height
4) Outer body size: 15” x 15” x 24”
5) Max working temperature :- 150.0 degree c
6) Bath capacity: - 5 sample at a time.
7) Bath volume : 20 Ltr capacity
8) Heater: - SS tubular heater.
9) Accuracy :- +/- 0.01 to +/- 0.03 degree c
10) Readability :- +/- 0.01 deg. c up to 99.99 deg. and 0.1 deg. c Up to 150.0 deg. c
11) Temperature controller :-
a. Temp. Is controlled by microprocessor based PID temp. Controller of Eurotherm or reputed make,
b. It is having dual display with solid state relay for switching on & switching off the heater.
12) Input power supply: 230 v ac, 50 Hz, 1 phase with 12 amp current rating.
13) Heating load: 2 kW
14) Thermocouple: -a. Calibrated RTD type thermocouple will be provided capable of measuring up to 150 deg. c at accuracy of +/- 0.01 deg. C
16) Safety Interlocks/ Relay: -
a. Overload safety cut-off
b. Safety for input power fluctuation
c. 1-phase indication lamp.
d. Emergency switch off
17) Construction: -
a. Double walled construction, thermally insulated with high density puff.
b. Powder coated external surface for esthetic appearance.
Accessories Will Be Supplied With Equipment: -
1) Universal viscometer holder -- 2 no (cat no hamco48s1)
2) suction bulb -- 1 no (cat no hamco48s2)
3) Glass fuse -- 1 no (cat no hamco48s3)
4) Glass viscometer with constant at 40,50 & 100 degree c of any size and any type with calibration certificate traceable to cannon oil USA (cat no hamco48s4) {on demand of customer only price extra}
Catalogue No | Product Description | Electrical Requirement |
Hamco 48h3 | High Temperature Round Kinematic Viscosity Bath(0 To 150 Deg. C) | 220-240v, 50/60hz |
|
Product Details:
Material | Steel |
Automation Grade | Automatic |
Frequency | 50-60 Hz |
Power Source | Electric |
Voltage | 220-380V |
Brand | HAMCO |
Power | Electric |
Display | Digtal |
TEST METHOD :- The sample is evaporated and condensed under controlled conditions, and observations are made of the temperatures at which various percentages are recovered and/or the percentages recovered at specified temperatures.
STANDARD :- Conforms to the specifications of: ASTM D86, D285, D4737 and related international specifications
CATALOGUE NO | PRODUCT DESCRIPTION | ELECTRICAL REQUIREMENT |
HAMCO 17A | DISTILLATION RANGE APPARATUS SINGLE | 220-240V, 50/60Hz, 10.8 AMP |
HAMCO 17AEXP | DISTILLATION RANGE APPARATUS SINGLE | 115V, 50/60Hz,20.8 AMP |
Product Details:
Usage/Application | Flash Point Determination |
Brand | HAMCO |
Automation Grade | Automatic |
Features | Automatic |
Temperature Range | 40 TO 400 DEG C |
Stirring Speed | 250 RPM |
Accuracy | 0.1 DEG C |
Power Supply | 230 V |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
Test Method: - Flash Point is lowest temperature at which application of the ignition source causes the Vapour of a specimen of the sample to ignite under the specified condition of the test.The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached.
Standard: - Conforms to the specifications of:ASTM D93; IP 34; ISO 2719
Features & Benefits:-
1) Temp. Range: 40 to 400° deg C.
2) Test Method: ISO 2719, ASTM D 93, IP 34, IS 1448 (P-21).
3) Ignition Source: Electrical ignitor with LPG gas connection.
4) Temperature Sensor: PT-100 in stainless steel sheath.
5) Flash Detector: CRC Thermocouple.
6) Controller: Touch Screen, Colour Display with PLC with audio visual alarm to check the machine. 3-wire RTD temperature sensor, free potential flame detector sensor as i/p. with automatic barometric reading correction.
7) Inbuilt storage memory for Flash Detection.
8) Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v or 24V DC, gear motor, vertical movement reciprocating to & fro motion.
9) Heater: 800 W, 230v.
10) Electrical ignition flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.
11) Equipment Overall Size (LxWxH): 280mm (W) X 530mm ( D ) X 415 mm ( H )
12) Equipment Gross Weight: 22 Kg.
13) Equipment supply will be 230 V Ac, 50 Hz with 15 amp capacity.
Features:-Single Action Setting: - The Flash Detection sensor and temperature sensor are permanently mounted on a lid, which allows easy setting of the specimen.Easy Operation: - Select a Test Mode and enter the expected flash Point. While instrument executes the test, you are free to do other lab work. The tester follows the exact procedures prescribed in the test method and the completion of the test cycle is signalled by buzzer. The test result is brightly shown in VFD and same will be stored in the HMI.
Automatically Shut The Machine And Horn The Buzzer In The Case:
1 | EFP+30oC or at 400oC is reached |
2 | Temperature sensor is found defective |
3 | Flash detector is found defective |
|
Accessories Will Be Supplied With Equipment:-
1) Pensky Martene Cup & Lid -- 1 No (Cat No Hamco30ac1)
2) Thermal Printer -- 1 No (Cat No Hamco30ac7)
3) Thermal Printer Roll -- 1 No (Cat No Hamco30ac8)
4) Pc Interface Cable – 1 No. (Cat No Hamco30ac9)
5) Software For Above-- 1 No. (Cat No Hamco30ac10)
6) Thermal Fuse – 1 No. (Cat No Hamco30ac5)
7) Signal Cable - 1 No. ( Cat No Hamco 30ac6)
Ordering Information:-
Catalogue No | Product Description | Electrical Requirement |
Hamco 30D | Automatic Pensky Martene Flash Point Apparatus | 220-240v, 50/60hz |
Product Details:
Brand | HAMCO |
Material | Stainless Steel |
Shipping weight | 26. 4 lbs (12kg) |
Shipping Dimensions | 2. 2 cu. Ft |
Dimension | 23x23x46 cm |
Net weight | 12 lbs (5. 5kg) |
Power | single phase, 220-240v, 50/60hz, 6. 0a or 115v, 12. 0a |
Standard | Conforms to the specifications of:ip 70. |
Type of Bath | Electrically heated immerssion heater. |
Max Working Temperature | 99 degree c |
Continous Working Temperature | 95 degree c |
Capacity | 1 sample at a time |
Heater | SS tubular immerssion heater |
Accuracy | +/- 3 degree c |
Readability | +/- 0. 5 degree c |
Input power supply | 230 v ac, 50 hz, 1 phase with 6 amp current rating. |
Test Method :- These viscometers are used to determine the viscosity of petroleum products. Two adoption of red wood viscometer are available no. 1 for liquids having red wood flow 20 seconds to 2000 seconds and no. 2 for liquids whose flow time exceeds 2000 seconds and no. 2 for liquids whose flow time exceeds 2000 seconds. Redwood viscometer is used for the determination of redwood viscosity and which can be converted to kinematic viscosity also. It is also used for observing the effect of temperature on viscosity by plotting graph.
Temperature Controller:-
a. By energy regulator which will turn on & off heater as time switch.
Stirrer : manual stirrer with stirrer blade for maintaining uniformity throughout chamber.
Top lid made of stainless steel with provision of mounting of one thermometer. .
Control Panel/Display:-
a. Energy Regulator .
b. Heater Indicator.
c. Kettle plug for heater connection.
Construction:-
a. Double walled construction, thermally insulated with inside body made of stainless steel outside gi.
b. Powder coated external surface for esthatic appearance.
accessories will be supplid with equipment :-
1) SS lid cover --1 no (cat no hamco 33ac1)
2) Thermometer collar -- 1 no (cat no hamco 33ac2)
3) Ball lock – 1 no. (cat no hamco 33ac3)
4) Glass redwood cup -- 1 no. (cat no hamco 33ac4)
5) Thermometer ip 8c with cal cert – 1 no. (cat no hamco33ac4)
6) Thermometer ip 9c with cal cert – 1 no. (cat no hamco33ac5)
7) Thermometer ip 10c with cal cert – 1 no. (cat no hamco33ac6)
8) Digital stopwatch – 1 no (cat no hamco33ac7)
spares required for 5 year trouble free operation :-
1) SS immersion heater -- 1 no. (cat no hamco33s1)
2) Glass redwood cup -- 1 no. (cat no hamco 33ac4)
3) Thermometer ip 8c with cal cert – 1 no. (cat no hamco33ac4)
4) Thermometer ip 9c with cal cert – 1 no. (cat no hamco33ac5)
5) Thermometer ip 10c with cal cert – 1 no. (cat no hamco33ac6)
6) Digital stopwatch – 1 no (cat no hamco33ac7)
Product Details:
Usage/Application | FLASH POINT |
Model | HAMCO30C |
Brand | HAMCO |
Temperature Range | 370 DEG C |
Stirring Speed | 120 & 250 RPM |
Accuracy | 0.1 DEG C |
Power Supply | 230 V |
Product Details:
Frequency | 50-60 Hz |
Voltage | 220-380V |
Material | Stainless Steel |
Standard | IS 1448(P-15) and ASTM D 130 |
Pid Temperature | 100 deg C |
Brand | Hamco |
Power | Electric |
Power Source | Electric |
Copper Corrosion Test Apparatus
Product Details:
Insulation Wall | Triple Wall |
Material | Stainless Steel |
Automation Grade | Automatic |
Brand | HAMCO |
Voltage | 220-380V |
Power Source | Electric |
Frequency | 50-60 Hz |
Test Method: -Determines a lubricant’s ability to prevent rusting of metal surfaces. Suitable for steam turbine oils, gear oils, hydraulic oils and other types of inhibited mineral oils. A steel test specimen is immersed in a heated mixture of sample oil and water which is stirred continuously during the test. After the test period the specimen is examined for rusting. The standard (ASTM D665) method uses a vertical specimen; the ‘horizontal disc method’ (ASTM D3603) uses both horizontal and vertical test surfaces.
Standard: - ASTM D665, D3603, D6158; NACE TM-01-72; IP 135; ISO 7120; DIN 51355, DIN 51585; FTM 791-4011, 791-5315; NF T 60-151
Features & Benefits:-1) Accommodates Four sample beakers,2) Microprocessor pid high accuracy temperature control,3) Testing Capacity: Four (4) 400mL sample beakers,4) Maximum Temperature: 95°C,5) Temperature Control Stability: ±0.5°C (±1°F),6) Drive Motor: 1⁄20hp induction motor,7) Bath Medium:30 Ltr white technical oil or Water.
Description :- Constant temperature bath with stirrers for rust preventing characteristics tests. Stirs sample-water mixtures at 1000rpm and controls temperature with ± 0.5°C (± 1°F) stability. Immerses test beakers at the proper depth per ASTM specifications. Microprocessor PID control provides quick temperature stabilization without overshoot, and the bath is protected by an overtemperature control circuit that interrupts power should bath temperature exceed a programmed cut-off point. Dual LED displays provide actual and setpoint temperature values in °C/°F format. Communications software (RS232, etc.), ramp-to-set and other enhanced features are available as extra cost options. Contact your Koehler representative for information. Stainless steel stirrer paddles are driven by a ball bearing type motor through an improved pulley drive-roller bearing arrangement. Paddles can be raised and lowered for placement of sample beakers in the bath. Includes test specimens, holders and beaker covers for ASTM D665 or D3603 testing (see specifications and ordering information). Stainless steel bath includes perforated support shelf for beakers and two-position cover plate that adjusts for either ASTM D665 or D3603 testing. Long-lasting polyester drive belt improves reliability. Drive train components are protected by a removable steel guard. All exterior surfaces have stainless steel or chemical resistant polyurethane enamel finishes.
Accessories Will Be Supplied With Equipment:-1) Steel Test Specimen (Model HAMCO 161AC1) -- 4 Nos.,2) Glass Beaker (HAMCO161AC2)-- 4 Nos.,3) Plastic Beaker Cover (HAMCO161AC3)– 4 Nos.,4) Chuck for Holding test specimen.(HAMCO161AC4)—1 No.
Electrical Requirement –· 220-240V, 50/60Hz, Single Phase, 10.0A,· OR 115V, 50/60Hz, Single Phase,20.0A
Dimension: - Ixwxh,in, (cm):-32X14X27 (83x36x69),Net Weight: 98 lbs (44 kg) Shipping Information:-Shipping Weight: 209 lbs (95 kg),Dimensions: 13 Cu. ft.
Product Details:
Usage/Application | For determining aniline point |
Brand | HAMCO |
Material | Borosilicate Glass |
Model Name/Number | HAMCO5B |
Shape | Rectangular |
Capacity | 100 Nos |
Temperature Range | Upto 150 Deg C |
Shipping Weight | 42 lbs (19.1kg) |
Shipping Dimensions | 5.7 Cu. ft |
Dimension- lxwxh,in.(cm) | 14.5x18.5x20.5 (37x22x53) |
Net Weight | 24 lbs (10.9kg) |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |
test method :- aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate. After the two phases become miscible, the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample.
standard :- conforms to: astm d611; ip 2; iso 2977; din 51775; ftm 791-3601.
features & benefits :-
for aniline point and mixed aniline point determinations according to method b. Stirs aniline-sample mixture in a borosilcate glass thin film tube suspended in a heating bath. Thin film of mixture flows over a light well illuminated by a variable 6v lamp. Adjust heating rate per specifications using accessory powertrol heater. When lamp filament brightens inside well, allow mixture to cool until the two phases separate as indicated by obscuring of the lamp filament. Consists of thin film tube; 400ml pyrex™ beaker; cover assembly with bath stirrer, sample pump rotor and cooling coil; 6v lamp with line cord; and drive motor. Positive drive pulley system rotates sample and bath stirrers. Accessory powertrol heater has variable stepless control and a reference dial for repeatable control of heating rate. Porcelain refractory top plate shields 75ow heater and has a positioning well for the borosilicate bath. Low voltage receptacle in heater housing accepts line cord of 6v lamp.
accessories will be supplied with equipment :-
1) outer jacket with cork -- 1 no (cat no hamco 5ac1)
2) tube with cork – 1 no (cat no hamco5ac2)
3) brass stirrer inner – 1 no (cat no hamco 5ac3)
spares required for 5 year trouble free operation :-
1) outer jacket with cork -- 2 no (cat no hamco 5ac1)
2) tube with cork – 2 no (cat no hamco5ac2)
3) brass stirrer inner – 2 no (cat no hamco 5ac3)
ordering information :-
catalogue no |
product description |
electrical requirement |
hamco 5 |
aniline point apparatus |
|
hamco 5ac1 |
outer jacket with cork |
|
hamco 43ac2 |
tube with cork |
|
hamco 43s1
|
brass stirrer inner |
|
Note: We also have a fully automatic, semi-automatic and manual model.
Product Details:
Brand | Hamco |
Material | SS |
Display | Digital |
Type | Portable |
Standard | As per ip 69, ASTM d 323 & d 1267 & as per is 1448(p-39) |
Product Details:
Standard | IP 14, ASTM D 524, & IS 1448(P-8) |
Bath | Round |
Size | 14 x 10 inch |
Heating Source | Electric |
Bulb | Five cocking bulb . |
Brand | HAMCO |
Power Source | Electric |
Voltage | 220-380V |
Frequency | 50-60 Hz |