Hindustan Apparatus Mfg. Company
Hindustan Apparatus Mfg. Company
Mumbai, Maharashtra
GST No. 27AAEFH0631E1ZW
TrustSEAL Verified
Call 08048966751 88% Response Rate
SEND EMAIL

Humidity Chamber

Leading Manufacturer of heating and cooling chamber without humidity, humidity chamber machine, stability chamber, heat chamber, isothermal bomb calorimeter and accelerated carbonation chamber from Mumbai.

HEATING AND COOLING CHAMBER WITHOUT HUMIDITY

HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
  • HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
  • HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
  • HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
  • HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
  • HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
  • HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
  • HEATING AND COOLING CHAMBER WITHOUT HUMIDITY
Get Best Quote
Approx. Price: Rs 1,65,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Capacity100 Litre
Automation GradeAutomatic
Display TypeDigital
Humidity RangeTemperature Range -20 DegreeC to 100 DegreeC , Temperature Accuracy +/- 1 DegreeC , Temperature Uniformity : +/- 2 DegreeC .
Model Name/NumberHAMCO46
Number Of Trays4
Country of OriginMade in India

CERTIFICATIONSOUR CHAMBERS ARE “CE” Certified Chambers . We as company is ISO 9001:2008 Certified Company. FEATURES Consist of Chamber (Hamco 46 series) + Ethernet Communication card + HMI (PLC 7”) + SOFTW-21 (Web based Software Part 11 21 CFR ) +DS (Door Access System) + SAFETY-1 RANGE/ HUMIDITY/ACCURACY / UNIFORMITYTemperature Range -20°C to 100°C , Temperature Accuracy +/- 1°C , Temperature Uniformity : +/- 2°C .No RH. RAMP RATE This chamber has No Ramp Up Time facility. Usually the ramp will be in the range of 0.3 to 0.7 Deg C/ Minute. Here Optimum Heat load considered.Hamco Suggest "The buyer is required to provide the heat load specifications prior to placing the order to ensure accurate system design and performance."CONSTRUCTION STANDARD MODEL Double walled , gap between walls filled with PUF Insulation. Inner Body made of SS 304 Mirror Finished, Outside GI Duly Powder Coated. Double door : Inner full Viewing door and outer door insulated with lock and key arrangement. 50mm Validation Port with silicon rubber seal to insert sensor for validation purpose. 3” Thick CFC Free Puff Insulation. Stainless steel Trays. Adjustable Tray Height adjustment. Unit Mounted on castor wheels with front lockarrangement. Stainless steel Rod Trays. Adjustable Tray Height adjustment.LIGHTINGFloroscent Light are provided , which automatically On when we open the door.CHAMBER PRINCIPLEAir circulation by Circulation Motor & Fan will continuously sucks the air from the chamber and Passes it through Air heater, Evaporator and through it back to chamber and same air will be recirculated to achieve desired Temperature stability inside chamber. Our design reduces the power consumption by 50% .ICH GUIDELINESFully Suitable to carry out Stability Studies For Conditions Such As : -20°C -10°C 0°C 25°C 50°C 75°C 100°CAny Temperature within Range of Temperature. Other Than this cycle Please Mention it before order.PROGRAMMABLE FEATURES This is Multi set point programmable chamber where you can program chamber based on different temperature, its ramp time, soak time and particular out put on/off during the step. We have 5 program we can make in this chamber. Each program can have 32 steps in it. Each program we can repeat 999 times.Hamco suggest "Kindly provide the detailed programmable cycle specifications prior to order to ensure proper configuration and testing of the heating and cooling chamber."APPLICATIONSApplication includes Electronics & Semiconductor, Aerospace, Pharmaceuticals , Automobile, Packing Medical Storage & R&D activity.HEATING & COOLING SYSTEM Heating system: U shaped Nichrome wire heater in SS Sheathing. Cooling system : Hermetically sealed CFC free Emerson compressor with R 134a refrigerant for Positive Cycle . Hermetically sealed CFC free Emerson compressor with R 404 refrigerant for Negative Cycle Two compressor Only. Air circulation : Flange Motor with Impeller and blower.Interior Illumination for working Area.There will be two nos of blower from 450 Ltr Onwords.To Help the customers to meet current regulatory requirements for the equipment , Hamco can provide DQ,IQ,OQ,PQ Protocols. This Protocol ensures that the system is properly installed, Operating as per our recommendations , Adequately documented and controlled according to regulatory requirements.Calibration certificate & Test certificate of critical components along with Operation , Maintenance Manual, Wiring diagram , chamber diagram, sensor position diagram provided.Operation Training of the instruments along with software installation and software Training is part of our Operation Qualification.To Help the customers to meet current regulatory requirements for the equipment , Hamco can provide DQ,IQ,OQ,PQ Protocols. This 
Request
Callback


Additional Information:

  • Item Code: HAMCO46S
  • Delivery Time: READY STOCK
  • Packaging Details: INNER DIMENSION : 45x45x45 CM OUTER DIMENSION : 60x95x110 CM
Yes! I am Interested

Humidity Chamber Machine

Humidity Chamber Machine
  • Humidity Chamber Machine
  • Humidity Chamber Machine
  • Humidity Chamber Machine
Get Best Quote
Approx. Price: Rs 1,10,000 / PieceGet Latest Price

Product Details:

Capacity100 Litre
Automation GradeAutomatic
Display TypeDigital
Number Of Trays2
Country of OriginMade in India
Frequency50Hz
Voltage220V
ApplicationLaboratory
PhaseSingle Phase

The Purpose of stability testing is to provide evidence on the how the quality of drug substances or drug product varies with time under the influence of environmental factors such as temperature, humidity and light and to establish a re test period for the drug substance or product under recommended storage conditions. Hence stability chamber serves as an important Quality attribute of the product. HAMCO Make GMP stability test chambers are especially built to Pass FDA and ICH Q1A compliance standards and have a reputation for reliability, quality and performance. Exceed FDA/ICH guidelines for long term , intermediate and accelerated stability studies. SPECIFICATIONS :- Temperature Range 5.0 °C to 60.0 °C. Accuracy +/- 0.1 °C. Uniformity +/- 1.0 °C Humidity range : 25% to 95% RH, Accuracy +/- 3% RH , Uniformity +/- 3% RH. Temperature Display : Digital LED 3 ½ digit, Resolution 0.1 deg C Humidity Display : Digital LED 3 ½ digit, Resolution 1% RH. Heating system: U shaped Nichrome wire heater in SS Sheathing. Cooling system : Hermetically sealed CFC free Emerson compressor with R 134a refrigerant . Humidity system : Non condensing type steam injection system with water level arrangement with insulation to save heat energy. Air circulation : Flange Motor with Impeller and blower. Interior Illumination for working Area. There will be two nos of blower from 450 Ltr Onwords.CONSTRUCTION :- Double walled , gap between walls filled with PUF Insulation. Standard Model : Stainless steel Mirror polished chamber and heavy guage Powder- coated CRC exteriorHAMCO44S -3 HAMCO44 G-3 3 90 45x45x45 60x95x110 2 110 165 230,50 1500 HAMCO44 S-4 HAMCO44 G-3 4 120 45x45x60 60x95x125 2 125 185 230,50 2000 HAMCO44 S-8 HAMCO44 G-8 8 200 60x60x60 80x110x125 2 170 240 230,50 2500 HAMCO44 S-12 HAMCO44 G-12 12 324 60x60x90 80x110x155 3 200 270 230,50 2500 HAMCO44 S-16 HAMCO44 G-16 16 450 60x60x125 80x130x175 4 275 355 230,50 4000 HAMCO44 S-21 HAMCO44 G-21 21 600 60x80x125 80x130x195 5 295 375 230,50 4000 HAMCO44 S-28 HAMCO44 G-28 28 800 80x80x125 100x130x210 5 325 415 230,50 4500 HAMCO44 S-34 HAMCO44 G-34 34 1000 80x80x155 100x130x220 5 350 450 230,50 4500 HAMCO44 S-53 HAMCO44G-53 53 1500 60X160X150 110X170X210 10 375 475 230,50 5000 HAMCO44 S-70 HAMCO44G-70 70 2000 80X160X150 130X176X210 10 400 500 230,50 5500  
Request
Callback
Yes! I am Interested

Stability Chamber

Stability Chamber
  • Stability Chamber
  • Stability Chamber
  • Stability Chamber
Get Best Quote
Approx. Price: Rs 90,956 / PieceGet Latest Price
Product Brochure

Product Details:

Capacity500 Litre
Automation GradeAutomatic
Display TypeDigital
Number Of Trays2
Country of OriginMade in India
Product TypeHumidity Chamber Manufacturers
Voltage220V
Frequency50Hz
PhaseSingle Phase

The Purpose of stability testing is to provide evidence on the how the quality of drug substances or drug product varies with time under the influence of environmental factors such as temperature, humidity and light and to establish a re test period for the drug substance or product under recommended storage conditions. Hence stability chamber serves as an important Quality attribute of the product.

HAMCO Make GMP stability test chambers are especially built to Pass FDA and ICH Q1A compliance standards and have a reputation for reliability, quality and performance. Exceed FDA/ICH guidelines for long term , intermediate and accelerated stability studies.SPECIFICATIONS :-Temperature Range 5.0 °C to 60.0 °C. Accuracy +/- 0.1 °C. Uniformity +/- 1.0 °CHumidity range : 25% to 95% RH, Accuracy +/- 3% RH , Uniformity +/- 3% RH.Temperature Display : Digital LED 3 ½ digit, Resolution 0.1 deg CHumidity Display : Digital LED 3 ½ digit, Resolution 1% RH.Heating system: U shaped Nichrome wire heater in SS Sheathing.Cooling system : Hermetically sealed CFC free Emerson compressor with R 134a refrigerant .Humidity system : Non condensing type steam injection system with water level arrangement with insulation to save heat energy.Air circulation : Flange Motor with Impeller and blower.Interior Illumination for working Area.There will be two nos of blower from 450 Ltr Onwords.CONSTRUCTION :-Double walled , gap between walls filled with PUF Insulation.Standard Model : Stainless steel Mirror polished chamber and heavy guage Powder- coated CRC exterior.GMP Model : Stainless steel Mirror polished chamber and exterior of dull finish stainless steel.Double door : Inner full Viewing door and outer door insulated with lock and key arrangement.50mm Validation Port with silicon rubber seal to insert sensor for validation purpose.3” Thick CFC Free Puff Insulation.Stainless steel Trays. Adjustable Tray Height adjustment.Unit Mounted on castor wheels with front lock arrangement.CONTROL PANEL :-Microprocessor based PID temp. controller with auto tune facility for precise control of temperature and humidity.Temp. Sensor : PT- 100 , RH sensor : direct capacitance type.Dedicated safety controller with separate sensor to cut off the supply in case of overshoot and undershoot of temperature giving audio visual alarm.Recorder data bank to store and print set values , process values , date and time of master controllers with variable print time intervals ( Optional)Alarm : Audio visual alarm if temperature deviates from the preset temperature.PC Interface communication card with RS 485 for temperature and humidity control system ( Hardware only) ( optional)SAFETY FEATURES :-Over heat temperature and humidity cut off with alarm.Low temperature and humidity alarm.Low boiler water level safeguard.Electrical overload compressor cutoff.Time delay for compressor switch on.Electrical short circuit breaker.UTILITIES (pre installation requisite):-Distilled water or DM Water Line. ( consumption will be 20 ltrs/24 hrs upto 450 ltr Model )Room temperature around machine preferably at 25 degree C.Stabilised input voltage of 230V Ac, 50 Hz, 20 Amps.Water drain line with ½” Nozzle to be provided at floor level.DATA RECORD :-21 CFR Part 11 compliant software with audit trial ( who did what and when is recorded)Multilevel Passwords.Data storage device has online and offline capabilities.Multi chamber data acquisition on single software.Tabular and graphical report, alarm deviation report.

Mean Kinetic temperature report and alarm deviation report.

Audit trial report.

Attractive reports and graphs.

Alarm report.

Time synchronisation.

Request
Callback
Yes! I am Interested

Heat Chamber

Heat Chamber
  • Heat Chamber
  • Heat Chamber
  • Heat Chamber
Get Best Quote
Approx. Price: Rs 1,75,000 / PieceGet Latest Price

Product Details:

ShapeSquare
Body MaterialStainless Steel
Usage/ApplicationIndustrial Ovens
Compatible Power5 Kw
High Temperature250 Degrees
PowerElectricity

A heat chamber is a controlled environment used for testing the effects of high temperatures on materials or products.
Request
Callback
Yes! I am Interested

Isothermal Bomb Calorimeter

Isothermal Bomb Calorimeter
  • Isothermal Bomb Calorimeter
  • Isothermal Bomb Calorimeter
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Country of OriginMade in India

Test method: - determines the ‘gross Calorfic value ‘of any solid or liquid sample by determining the water equivalent by burning 1 gm of known CV sample.Standard: - confirm to the specification ASTM D 4809, D 240, DE711, IS -1350- 1966, BS 1016 PART 5-1967, IP 12/63 T.Features & benefits: -1)Type of method: - isothermal.2)Method of detecting temp. Rise : automatic3)Method of detecting calorific value : automatic4)Touch Screen PLC.5)Automatic measurement and calculation of Calorfic value / water equivalent.6)21 x 4 character lcd display7)Thermal printer interface with printout report.8)Auto alarm on completion of test.9)Pc interface for data recording.10)Weight of the sample to be filled by keyboard.11)Calorimeter vessel made of Copper electroplated.12)Bomb support to ensure correct positioning of bomb in vessel.13)Ambient working temp range : 15 to 35 degree c14)Heat capacity :- 5800 to 6500 cal/deg c15)Process time: - 10 to 12 minute.16)Temperature resolution :- 0.0001 deg c17)Oxygen bomb endure pressure : 300 kg/cm18)Humidity requirement : less than 85%
19)Power supply: 230a VC, 50 Hz, 10 amp.20)Heating load: 2 kW.21)Control panel/display :-a.Digital display of temperature.b.Auto temp. Rise detection based on microprocessor chip based. User has to press one button and is free for doing other thing while microprocessor will take reading automatically.c.Automatic reading for temp. Rise calculation.d.All the necessary interlock for stirrer, ignition wire continuity, wire loose, over load etc.e.Electrode short indication.f.Continuity test indication.g.Auto stop of the stirrer after completion of test.h.Buzzer horn after completion of the test.22)Safety interlocks/ relay :-a.Over load protection.b.Electrode short protection & indication.c.1-phase indication lamp.d.Emergency switch off23)Construction :-a.Double walled construction, thermally insulated by pouring approx. 18 ltr water in the outer jacket.b.Made of full stainless steel.Accessories will be supplied with equipment: -1.SS bomb (cat no : hamco 6ac 1)2.Calorimeter vessel with bomb support.3.Insulated outer jacket with calorimeter vessel support.4.Combined lid for outer jacket & calorimeter vessel.5.Connecting tubes (copper / flexible) for filling oxygen in the bomb: 3 nos.6.Spanner for oxygen valve & copper tube connection.7.Oxygen control valve. (cat no : hamco 6ac 2)8.Pressure gauge on stand with bomb lid stand.9.Safety device.10.Pellet press. (cat no : hamco 6ac 3)11.Stirrer unit12.Automatic electronic firing unit with digital Beckmann thermometer. (microprocessor based)13.Connecting wire [electrical].
14.Hook for lifting bomb. (cat no : hamco 6ac 4)15.Crucible. [stainless steel] (cat no : hamco 6ac 5)16.Cotton reel(cat no : hamco 6ac 6):01 no. (approximately 200 meters)17.Bomb ‘o’ ring (cat no: hamco 6ac 7): 01 no.18.Teflon tape: 01 no.19.Valve body ‘o’ ring (cat no: hamco 6ac 8): 01 no.20.Ignition wire (cat no: hamco 6ac 9): 100 meters.21.Schrader valve (cat no: hamco 6ac 10): 01 nos.22.Bursting discs for safety device 12 nos: 1 set. (cat no : hamco 6ac 11)23.Benzoic acid of known calorific valve. { 6319 cal / gram }24.Valve key. {4 sided key used for replacing/tightening Schrader valve, see (p) in precautions on page 12}25.Printer26.Pc interface cable.27.Operating manual.Spares required for 5 year trouble free operation: -1)Cotton reel (cat no: hamco 6ac 6):05 no. (approximately 200 meters)2)Bomb ‘o’ ring (cat no: hamco 6ac 7): 02 no.3)Valve body ‘o’ ring (cat no: hamco 6ac 8): 02 no.4)Ignition wire (cat no: hamco 6ac 9): 100 meters.5)Schrader valve (cat no: hamco 6ac 10): 01 nos.Electrical requirement –•220-240v, 50/60hz, single phase, 10.9a•Or 115v, 50/60hz, single phase, 20.8a
Request
Callback
Yes! I am Interested

ACCELERATED CARBONATION CHAMBER

ACCELERATED CARBONATION CHAMBER
    Ask For Price
    X

    Product Videos

    Watch More Videos

    Explore More Products

    View All Products
    Tell Us What Are You Looking For ?




    Reach Us
    Chirag Shah (CEO)
    Hindustan Apparatus Mfg. Company
    12/2, Patel Industrial Estate, Gokhiware
    Mumbai - 401208, Maharashtra, India
    Get Directions

    Call Us


    Send E-mail